Перегляд за автором "Shlyakhov, I.N."

Сортувати за: Порядок: Результатів:

  • Rogov, Ju.V.; Shevchenko, V.A.; Shlyakhov, I.N.; Shramenko, B.I.; Tenishev, A.Eh.; Torgovkin, A.V.; Uvarov, V.L.; Zhiglo, V.F. (Вопросы атомной науки и техники, 2015)
    Possibility of a dosimetry method for high-energy bremsstrahlung radiation in the range up to МGy and higher by activation of a detector from indium via the ¹¹⁵In (γ,γ') ¹¹⁵mIn reaction with determination of absorbed dose ...
  • Dovbnya, N.A.; Karasyov, S.P.; Kutny, V.E.; Rybka, A.V.; Shlyakhov, I.N.; Uvarov, V.L. (Вопросы атомной науки и техники, 2002)
    The radiation detectors based on wide-zone semiconductor CdTe (CdZnTe) monocrystals have promising advantages for their application in investigation (characterization) of radioactive waste. Among these advantages there are ...
  • Karasyov, S.P.; Pomatsalyuk, R.I.; Tenishev, A.Eh.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N. (Вопросы атомной науки и техники, 2006)
    The regulatory documents for a number of technological processes (sterilization and others) require that a continuous control and archiving of beam scanning regime should be provided. To meet these conditions at the ...
  • Kutny, V.E.; Nikiforov, V.I.; Opalev, O.A.; Rogov, Yu.V.; Rybka, A.V.; Shevchenko, V.A.; Shlyakhov, I.N.; Strelnitsky, V.E.; Tenishev, A.Eh.; Uvarov, V.L. (Вопросы атомной науки и техники, 2014)
    Results of a study of dosimetry characteristics of a prototype of the detector based on a polycrystalline diamond film (CVD-diamond) produced in NSC KIPT are summarized. The techniques of the detector calibration against ...
  • Kutny, V.E.; Vierovkin, A.A.; Rybka, A.V.; Dudnik, S.F.; Opalev, O.A.; Strelnitsky, V.E.; Zakharchenko, A.A.; Tenishev, A.Eh.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N. (Вопросы атомной науки и техники, 2016)
    The prototypes of the coordinate-sensitive semiconductor detectors based on polycrystalline diamond films (CVD-diamond) have been manufactured in the NSC KIPT. In this communication, a version of the detector with the ...
  • Pomatsalyuk, R.I.; Shevchenko, V.A.; Shlyakhov, I.N.; Tenishev, A.Eh.; Uvarov, V.L. (Вопросы атомной науки и техники, 2015)
    The hard- and software interfaces that provide on-line control and archiving of the basic parameters of the medical device sterilization (electron energy, beam current, width and shape of the beam scan, the conveyor speed ...
  • Biller, E.Z.; Nikiforov, V.I.; Tenishev, A.Eh.; Torgovkin, A.V.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N.; Shramenko, B.I.; Zhiglo, V.F. (2010)
    The novel type of the converter to transform a high-density electron beam into bremsstrahlung has been developed and investigated. To increase the thermal stability of the converter by means of a growth of the heat-exchange ...
  • Dikiy, N.P.; Lyashko, Yu.V.; Uvarov, V.L.; Shlyakhov, I.N.; Malets, Eu.B. (Вопросы атомной науки и техники, 2004)
    The present report deals with experimental investigations into possible processes of accumulation of radioactive by-products (RBPs) during 99Mo/99mTc production at an electron linac. Foils from natural molybdenum (a target) ...
  • Dikiy, N.P.; Dovbnya, N.A.; Repikhov, O.A.; Shlyakhov, I.N.; Uvarov, V.L.; Kravchenko, Ja.N. (Вопросы атомной науки и техники, 2001)
    Gamma-chambers are widely used in medicine diagnostics to obtain an organ image investigated by means of the scintigraphy method. A radionuclide Tc-99m which is accumulated in the organ and irradiates photons with the ...
  • Karasyov, S.P.; Maryokhin, S.V.; Tenishev, A.Eh.; Uvarov, V.L.; Fursov, G.L.; Shevchenko, V.A.; Shlyakhov, I.N.; Tsvetkov, I.I. (Вопросы атомной науки и техники, 1999)
    One of the most actual problems of the metrology is obtaining of information about several parameters measured with the help of one sensor. With the reference to the metrology of the electron radiation on the industrial ...
  • Pomatsalyuk, R.I.; Shevchenko, V.A.; Shlyakhov, I.N.; Tenishev, A.Eh.; Titov, V.Yu.; Titov, D.V.; Uvarov, V.L.; Zakharchenko, A.A. (Вопросы атомной науки и техники, 2017)
    At an electron accelerator, the particle energy is one of critical parameters in the technological processes, as well as when conducting the radiation tests. The report presents the results of modernization of beam ...
  • Karasyov, S.P.; Nikiforov, V.I.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N. (Вопросы атомной науки и техники, 2006)
    The paper describes the methods and devices proposed for measuring the main parameters of high-power highenergy bremsstrahlung sources. It has been suggested that space-energy characteristics of radiation should be ...
  • Pomatsalyuk, R.I.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N. (Вопросы атомной науки и техники, 2017)
    Continuous control and monitoring of critical parameters of radiation processing of products is one of the requirements of the international standard ISO 11137. The current system to monitoring the parameters of radiation ...
  • Karasyov, S.P.; Nikiforov, V.I.; Pomatsalyuk, R.I.; Tenishev, A.Eh.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N.; Malets, E.B. (Вопросы атомной науки и техники, 2006)
    Great deals of present-day radiation technologies that use electron accelerators involve the procedure of transporting the products under treatment across the irradiation zone normally to the beam scanning plane. The main ...
  • Nikiforov, V.I.; Shlyakhov, I.N.; Shevchenko, V.A.; Tenishev, A.Eh.; Uvarov, V.L. (Вопросы атомной науки и техники, 2019)
    The conditions of application of a Compton direct-charge detector (DCD) for monitoring of intensity of the highenergy bremsstrahlung (X-ray) radiation are studied. A method is described for calculation of characteristics ...
  • Dikiy, N.P.; Kushnir, V.A.; Lyashko, Yu.V.; Mitrochenko, V.V.; Perezhogin, S.A.; Rogov, Yu.V.; Tenishev, A.Eh.; Torgovkin, A.V.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N.; Shramenko, B.I. (Вопросы атомной науки и техники, 2013)
    Radioactive isotopes of palladium (¹⁰³Pd) and rhenium (¹⁸⁶Re and ¹⁸⁸Re) have found wide use in nuclear medicine. The present report deals with the conditions for their production by a photonuclear method at an electron ...
  • Yeran, L.V.; Karasyov, S.P.; Nikiforov, V.I.; Pomatsalyuk, R.I.; Tenishev, A.Eh.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N. (Вопросы атомной науки и техники, 2004)
    A continuous mode of product transportation into the radiation zone of the electron accelerator with a scanned beam is attained by means of a remote loading of the conveyor. To keep an assigned distribution of the ...
  • Karasyov, S.P.; Pomatsalyuk, R.I.; Shevchenko, V.A.; Shlyakhov, I.N.; Tenishev, A.Eh.; Uvarov, V.L. (Вопросы атомной науки и техники, 2001)
    One of advanced ways of isotope production for medicine is using of bremsstrahlung of the electron accelerator [1]. Therewith, this technology requires development of special target units, that can be operated under high ...
  • Yeran, L.V.; Karasyov, S.P.; Pomatsalyuk, R.I.; Sayenko, S.Yu.; Shevchenko, V.A.; Shlyakhov, I.N.; Tenishev, A.Eh.; Uvarov, V.L. (Вопросы атомной науки и техники, 2001)
    There is a necessity to provide an immobilization of the long-lived radioactive waste into radiation-resistant structure (a cement matrix, container capsule, geological disposal environment and so on) for it safely disposal. ...
  • Butenko, A.A.; Karasyov, S.P.; Pomatsalyuk, R.I.; Tenishev, A.Eh.; Uvarov, V.L.; Shevchenko, V.A.; Shlyakhov, I.N.; Tsvetkov, I.I. (Вопросы атомной науки и техники, 1999)
    For metrological support of radiation technological processes based on braking radiation (bremsstrahlung) of the electron accelerator necessary is continuous monitoring of next radiation parameters: energy stream and energy ...